.1 The arrangement of machinery spaces shall be
so that safe storage and handling of flammable liquids is ensured.
.2 All spaces where oil-consuming installations
settling tanks or daily service fuel tanks are located shall be easily
accessible and well ventilated.
.3 Where leakage of flammable liquids may occur
during normal service or routine maintenance work, special arrangement
shall be made to prevent these fluids from reaching other parts of
the machinery where danger of ignition may arise.
.4 Materials used in machinery spaces shall not
normally have properties increasing the fire potential of these rooms.
.5 Neither combustible nor oil-absorbing materials
shall be used as flooring, bulkhead lining, ceiling or decks in the
control room, machinery spaces, shaft tunnel or rooms where oil tanks
are located. Where penetration of oil products is possible, the surface
of the insulation shall be impervious to oil or oil vapours.