3 In paragraph 15.8.25.1, the reference to paragraph "1.3.18" in the
second set of brackets is replaced by "1.3.19".
4 Section 15.15 is replaced by the following:
-
"15.15 Hydrogen sulphide (H2S) detection
equipment for bulk liquids
-
Hydrogen sulphide (H2S) detection
equipment shall be provided on board ships carrying bulk
liquids prone to H2S formation. It should be
noted that scavengers and biocides, when used, may not be
100% effective in controlling the formation of
H2S. Toxic vapour detection instruments complying
with the requirement in 13.2.1 of the Code for testing for
H2S may be used to satisfy this
requirement."