Clasification Society Rulefinder 2016 - Version 9.25
Clasification Society Rules and Regulations - Rules and Regulations for the Classification of Offshore Units, January 2016 - Part 7 SAFETY SYSTEMS, HAZARDOUS AREAS AND FIRE - Chapter 2 Hazardous Areas and Ventilation - Section 4 Enclosed and semi-enclosed spaces with access to a hazardous area |
||
![]() Section 4 Enclosed and semi-enclosed spaces with access to a hazardous area4.1 General4.1.1 As far as practicable, access doors or other openings should not be provided between a non-hazardous space and a hazardous area or space, or between a Zone 2 space and a Zone 1 space. 4.1.2 Where such openings are necessary, an enclosed or semi-enclosed space with a direct access door or opening leading to an area or space which is of a greater hazard classification is to be regarded as the same hazard classification as the area or space into which this door or opening leads, except where suitable arrangements as permitted by Pt 7, Ch 2, 4.1 General 4.1.3 are provided. 4.1.3 An enclosed space with direct access to a:
4.1.4 Where one of the doors specified in Pt 7, Ch 2, 4.1 General 4.1.3 is required to be weathertight or watertight and the provision of a self-closing mechanism would be impracticable, consideration will be given to waiving the requirement for this door to be self-closing, provided the door is normally kept closed and is provided with a notice to this effect. |
||
|
||
|