3.6.4 External openings
Clasification Society 2024 - Version 9.40
Statutory Documents - IMO Publications and Documents - International Codes - 1979 MODU Code – Code for the Construction and Equipment of Mobile Offshore Drilling Units – Resolution A.414(XI) - Chapter 3 – Subdivision, Stability and Freeboard - 3.6 Watertight integrity - 3.6.4 External openings

3.6.4 External openings

  .1 Where watertight integrity is dependent on external openings which are used during the operation of the unit, while afloat, they should comply with the following:

  • .1 Openings, the lower edges of which are not to be submerged, include air pipes (regardless of closing appliances), ventilators, ventilation intakes and outlets, non-watertight hatches and doorways not fitted with watertight closing appliances; and

  • .2 Openings such as manholes fitted with close bolted covers, small hatchesfootnote and sidescuttles of the non-opening type may be submerged.

  .2 The requirements of 3.6.3.2 should apply where the watertight integrity is dependent on external openings which are permanently closed during the operation of the unit, while afloat.


Copyright 2022 Clasifications Register Group Limited, International Maritime Organization, International Labour Organization or Maritime and Coastguard Agency. All rights reserved. Clasifications Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause as 'Clasifications Register'. Clasifications Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Clasifications Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.