4.2.1 harmonic distortion, for electrical equipment shall be defined for normal, abnormal
operating and emergency conditions for each circuit.
4.2.2 Voltage and frequency permanent and transient limits are to be set giving due
consideration to variations in electrical power generation and loads during normal
and abnormal operating conditions, e.g. the starting and stopping of generators and
consumers.
4.2.3 For electrical installations that may be supplied by batteries the quality of power
supplies shall be defined throughout the specified charge and discharge cycles of
the batteries.
4.2.4 The submarine, equipment and components that are required to operate on each circuit
are to be identified. They shall be able to operate with the defined levels of
electrical power supply variation for that circuit or be fitted with suitable
protection measures.
4.2.5 Electrical equipment insulation resistance shall be sufficient for the full range of
conditions defined.