* The net scantlings should provide the structural
strength required to sustain the design loads, assuming the structure
is in intact condition and without any corrosion margin. However,
when assessing fatigue and global strength of hull girder and primary
supporting structures, a portion of the total corrosion margin may
be added to the net scantlings to reflect the material thickness that
can reasonably be expected to exist over the design life.