Footnote
Clasification Society 2024 - Version 9.40

Footnote

For material thickness of more than 25 mm, Charpy V-notch tests shall be conducted as follows:

Material thickness (mm) Test temperature (°C)
25 < t ≤ 30 10°C below design temperature or -20°C, whichever is lower
30 < t ≤ 35 15°C below design temperature or -20°C, whichever is lower
35 < t ≤ 40 20°C below design temperature
40 < t Temperature approved by the Administration or recognized organization acting on its behalf

The impact energy value shall be in accordance with the table for the applicable type of test specimen.

Materials for tanks and parts of tanks which are completely thermally stress relieved after welding may be tested at a temperature 5°C below design temperature or -20°C, whichever is lower.

For thermally stress relieved reinforcements and other fittings, the test temperature shall be the same as that required for the adjacent tank-shell thickness.


Copyright 2022 Clasifications Register Group Limited, International Maritime Organization, International Labour Organization or Maritime and Coastguard Agency. All rights reserved. Clasifications Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause as 'Clasifications Register'. Clasifications Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Clasifications Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.