9.1.1 Electrotechnical
systems are to be designed and approved in accordance with the requirements
of the Control and Electrical Engineering Sections of Pt 16 Control and Electrical Engineering of the SSC Rules.
9.1.2 The engines
are to be fitted with adequate safety monitoring and control devices
in respect of speed, temperature, pressure and other operational functions
and are to be agreed with LR.
9.1.4 Where the
primary engine shutdown controls are mounted within engine spaces,
engine shutdown capability must be retained during flame tests for
a period of five minutes.
9.1.5 Independent
means are to be provided for shutting off the fuel supply outside
the fire retardant bulkheads of the engine spaces (see ISO
15540 and 15541, as applicable).