7.3.1 In passenger ships to which the International
Convention for the Safety of Life at Sea, 1974, applies, doors should
comply with regulations II-l/13 and 16 of this Convention.
7.3.2 In ships to which the International Convention
on Load Lines, 1966 or the Protocol of 1988 relating thereto, as amended,
as applicable, applies, doors should comply with regulation
12 of this Convention.
7.3.3 In fishing vessels to which the 1993 Torremolinos
Protocol applies, doors should comply with regulation
II/2 and regulation II/4 of
this Protocol.
7.3.4 In decked fishing vessels of 12 m in length
and over but less than 24 m in length:
-
.1 Watertight doors may be of the hinged type
and should be capable of being operated locally from each side of
the door. A notice should be attached to the door on each side stating
that the door should be kept closed at sea.
-
.2 All access openings in bulkheads of enclosed
deck erections, through which water could enter and endanger the vessel,
should be fitted with doors permanently attached to the bulkhead,
framed and stiffened so that the whole structure is of equivalent
strength to the unpierced structure, and weathertight when closed,
and means should be provided so that they can be operated from each
side of the bulkhead.
-
.3 The height above deck of sills in those doorways,
companionways, deck erections and machinery casings situated on the
working deck and on superstructure decks which give direct access
to parts of that deck exposed to the weather and sea should be at
least equal to the height of hatchway coamings as specified in 7.1.3.8.
-
.4 Where operating experience has shown justification
and on approval of the competent authority, the height above deck
of sills in the doorways specified in 7.3.4.3 except those giving
direct access to machinery spaces, may be reduced to not less than
150 mm on superstructure decks and not less than 380 mm on the working
deck for vessels 24 m in length, or not less than 150 mm on the working
deck for vessels of 12 m in length. For vessels of intermediate length
the minimum acceptable reduced height for sills in doorways on the
working deck should be obtained by linear interpolation.